CANALYZER MB

Inspections

Technology

The Canalyzer MB is bottom only dud detector. This machine measures the deflection on one end of the can at high speeds. Our special high-frequency scanning technology allows the Canalyzer to accurately profile the can end over several hundred to several thousand data points. This scanning technology allows the Canalyzer to be able to detect a leaking can, even if there is minimal change between a good can and a leaking can.

Features

  • The Canalyzer MTB has its own precision integrated conveyor for accurate inspections.
  • Displayed measurements of 0.001 inch can be compared to depth gauge reading for real world feedback.
  • Tests both ends of the can against independent control limits.
  • SLC controls automatic selection of set points can be used to start a new code based on the standard deviation in seconds. Trending set points or percentage kick outs can also be maintained automatically.
  • Bottom inspection
  • Inspects 2- and 3-piece cans
  • Inspects any can type and size Including EZO
  • Quick and easy changeovers
  • High speed (1200 standard, 1600 custom)
  • Precision sensor adjustments for accurate inspections and fast changeover times
  • Inspects large variety of can types and sizes
  • Wear parts are made from a static dissipating material to eliminate sensor interference.
  • Precision integrated conveyor
  • Displays measurements in real units (0.001″ increments)
  • Warehouse and washdown ( stainless steel and engineered plastics)
  • versions available
  • Conveyor extensions available in several styles and lengths

Specifications

Specifications
Operating Speed1200 (Standard)/ 1600 (High speed) inspections per minute max
Power Requirements 100-250 VAC , 50 or 60 Hz single phase, isolated incoming power for Control
240-480 VAC 50 or 60 Hz three phase power for motor
Pneumatic Requirements35-50 psi; ¼” standard (Options available)
Spacing RequirementsZero backline pressure from containers. Accumulation should stop 20 inches from discharge
DisplayTouchscreen Display
Operating ConditionsStable Ambient Temperature: 32º to 122º F (0º - 50º C)
CommunicationsRS-232 report sending capability (optional)
EnclosureNema 12 std (Nema 4, IP 65 optional )
Length40.0” Standard; conveyer extensions available (32.0”, 40.0”, 48.0”)
Height32.0” Standard +/- 2.0” (extensions available)
EjectPneumatic cylinder with soft bumper
InterfaceIntuitive with multiple access levels, Touchscreen (HMI) interface
ConstructionStainless Steel, engineered plastics and Aluminium (Durable construction for the food and beverage industries)