CANALYZER MT

Inspections

Technology

The Canalyzer MT is easily installed over table top conveyors. No contact of can lid for smooth transition through the test area Speeds up to 1600 cans per minute can be accommodated New inductive impedance technology provides a linear output without calibration or drift found in older technologies. Can deflections and limits are displayed in .001 inch increments to provide accurate, easy to understand standards that can be matched to a depth gauge. Trending set points or percentage kick outs cans also be maintained automatically. Product and container changeovers can be accomplished in seconds to minimize the effort and time spent by mechanics and technicians.

Canalyzer MT Brochure

Features

  • The Canalyzer MT installs easily over existing flat conveyors.
  • Displayed measurements of 0.001inch can be compared to depth gauge reading for real world feedback.
  • SLC controls automatic selection of set points can be used to start a new code based on the standard deviation in seconds. Trending set points or percentage kick outs can also be maintained automatically.
  • Top Inspection
  • Inspects 2/3-piece cans and glass jars
  • Inspects any can type and size Including EZO
  • Quick and easy changeovers
  • Precision sensor adjustments for accurate inspections and fast changeover times
  • Inspects large variety of can types and sizes
  • Wear parts are made from a static dissipating material to eliminate sensor interference.
  • High speed (1200 standard, 1600 custom)
  • Displays measurements in real units (0.001″ increments)
  • Portable Construction
  • Warehouse and washdown ( stainless steel and engineered plastics) versions available

Specifications

Specifications
Operating Speed1200 (Standard)/ 1600 (High speed) inspections per minute max
Power Requirements 100-250 VAC , 50 or 60 Hz single phase, isolated incoming power for Control
240-480 VAC 50 or 60 Hz three phase power for motor
Pneumatic Requirements35-50 psi; ¼” standard (Options available)
Spacing RequirementsZero backline pressure from containers. Accumulation should stop 20 inches from discharge
DisplayTouchscreen Display
Operating ConditionsStable Ambient Temperature: 32º to 122º F (0º - 50º C)
CommunicationsEthernet/VNC Capability
EnclosureNema 12 std (Nema 4, IP 65 optional )
LengthN/A
Height32.0” Standard +/- 2.0” (extensions available)
EjectPneumatic cylinder with soft bumper
InterfaceIntuitive with Key Lock Feature, Touch screen (HMI) interface available
ConstructionStainless Steel, engineered plastics and Aluminium (Durable construction for the food and beverage industries)